The following are the benefits of the PLC Counter Modules of MSX-E :
• The modules of MSX-E are applied during the term of length measurement and as a module of multi¬occupation counter.
• The MSX-E modules be possible to be flown and synchro¬nized in the sunken space adjoining the basement of s (micro second) and on that account allow the concurrent acquisition of measuring posture and values.
• The MSX-E modules be obliged been built up for use in uncivil environmental conditions. The modules of I/O (Input / Output) be possible to be used in the expanded temperature range from -40 degree Celsius to +85 station Celsius (-40 °C to +85 °C). They give to protection class IP 65 (class Internet Protocol 65) and are consequently wary against splash dust and water. The I/O (Input / Output) modules normally class without the "protection" of switch cabinets. This reduces require to be paid and space in the production large room or in the measuring room. In joining, the modules are provided with unlike each other protective circuits. This contains an optical detachment of up to 1,000 V and a curt circuit and reverses polarity protection.
• Monitoring and parameterization from one side web server save time, in exacting which time setting up measuring facilities, and flow flexibility. The modules of ADDI-DATA consequently bestow measuring values directly on the monitor of the technician's Personal Computer (PC), in opposition to instance check whether measuring values near and are transferred to the PLC (Programmable Logic Controller).
• Transmission Control Protocol or Internet Protocol (TCP/IP) allows a unblended link to the PLC (Programmable Logic Controller) and the badger-free forwar¬ding of measuring premises to the remote maintenance or IT proportion (Information Technology level) with password and encryption.
• Data storage at On-enter RAM (Random Access Memory).
• Software keeps updated have power to be simply installed at any time without ceasing the modules of MSX-E.

The returns range contains modules with added functionalities: digital Input / Output or digital I/O (24 V) in multifunction contrary module; module input analog, e.g. as far as concerns the laser sensors acquisition; module of analog output. A module Ethernet as being the temperature acquisi¬tion is in scrutiny. The connection of module is natural, as the connection block is alike for all modules. This includes a 24 V gift supply, Ethernet, and trigger/synchronization.